Inside the appliance
Induction cooktop interface temperature sensor. In plain English.
A Bertazzoni TFT induction cooktop has a temperature sensor on the glass user interface. If it reads more than 85 degrees C, the hob switches off and shows ER21. The error clears below 75 degrees C. The manual also asks you to check the interface insulation.

Where it fits.
Induction cooktop interface temperature sensor in the appliance
The sensor sits in the touch glass user interface, as the ER21 row describes.
This photo stands for the kind of component only. It cannot say which replacement suits your model.
What looks different when this system needs a look.
Induction cooktop interface temperature sensor trouble may show up together with weaker performance or a code that keeps coming back. A test is needed to decide whether this component is the cause.

Bertazzoni induction cooktop will not heat
Check the power first, then the panel. The manual ties a cooktop that stays cold to lost power, demo mode, a pan the zone cannot detect, or a locked panel showing L. Work through those four before blaming a component.

Bertazzoni induction cooktop turns off by itself
A zone or the whole hob that switches off during cooking points to heat or water on the controls. The manual names an overheated hob with blocked cooling air below it, and water or pans on the glass controls for ER03. Clear both before you call.
Owner care, within the model instructions.
Turn the appliance off and unplug it before any check you do yourself. Look out for pooled water and sharp debris. Never touch a wet plug or the electrical parts, take off a service panel or go past what your model’s instructions allow.
- 1
Let it cool
Wait until the interface drops below 75 degrees C, about 167 degrees F.
- 2
Clear the glass
Remove hot pans and objects from the control area.
- 3
Check what is below
The manual says an overheated hob can mean blocked cooling underneath, such as bulky items in a drawer.
- 4
Tell us if it repeats
Give the technician the code and how long the hob had run.
Cleaning or replacement?
Leave internal testing to a technician.
ER21 returns after the hob has cooled.
ER03 shows with the glass dry and clear.
The hob will not switch on at all.
Arrange a diagnosticSources and model boundaries.
These sources back up the Induction cooktop interface temperature sensor advice. Read the manual that belongs to your model.
- INSTALLATION MANUAL / USER AND MAINTENANCE MANUAL / INDUCTION COOKTOP
- INSTALLATION MANUAL / USER AND MAINTENANCE MANUAL / INDUCTION COOKTOP
- INSTALLATION MANUAL / USER AND MAINTENANCE MANUAL / INDUCTION COOKTOP
Follow the book written for your own model. Read how we research these pages.
What triggers ER21?
The sensor on the user interface read above 85 degrees C, per the table on page 37. The hob then switches off.
When can I switch it on again?
Once the temperature falls below the limit, which the manual gives as 185 F or 85 C. The error disappears below 75 C.
Is E2 a separate code?
The manual prints E2 and ER21 as one pair, described as overtemperature, switching off.
What is ER03?
The hob switches off after 10 seconds, and the manual blames water or pans on the user interface.
Bertazzoni codes, symptoms, parts, service calls
Turn what the display says into a sensible next step.
ER21
ER21 on a Bertazzoni TFT induction cooktop means the temperature sensor on the user interface read above 85 °C and the hob shut off. Let it cool below 75 °C, then check the interface insulation.
Bertazzoni induction cooktop will not heat
Check the power first, then the panel. The manual ties a cooktop that stays cold to lost power, demo mode, a pan the zone cannot detect, or a locked panel showing L. Work through those four before blaming a component.
Cooktop repair
Book a diagnostic for your exact model, done at the appliance.
Find your metro
Office details, and what to tell us about getting in.