Start from the symptom
Bertazzoni wine cooler wine cabinet will not turn on.
The manual's first checklist for a wine column that does not work is short: power at the appliance, power at the socket, the Unit key, and a clean condenser. Do those before anything else, then read the display for a code.

Start with safe observations.
Turn the appliance off and unplug it before any check you do yourself. Look out for pooled water and sharp debris. Never touch a wet plug or the electrical parts, take off a service panel or go past what your model’s instructions allow.
- 1
Check the connection
The manual asks if the cabinet is plugged in and if the socket is live.
- 2
Press the Unit key
Confirm the Unit key is active. The manual refers to the key on the main control panel.
- 3
Look at the condenser
The manual also asks whether the condenser is clean. Dust behind the toe kick grille is a common cause for a hot, struggling unit.
- 4
Read any message
A malfunction is usually shown on the display. Touch Alarm to see the message and its error number, which stays for 3 seconds.
- 5
Note Power Failure
If the display says Power Failure, the cabinet restarted automatically after an outage and shows the highest recorded temperatures.
More about this symptom.
What should I check when the cabinet does nothing?#
Work through the manual's questions: is the appliance connected, does the socket have power, is the Unit key activated, and is the condenser clean. Many no-start reports end at the first two. 1
Where do I see the reason?#
On the display. A malfunction is usually indicated there, and problems the owner cannot solve show as a malfunction code. Touch Alarm to see the message with its error number. 12
What does Power Failure tell me?#
It reports a prolonged interruption of electrical power. The cabinet restarts on its own and shows the highest temperatures it recorded. Check your bottles' temperature range after any long outage. 2
When does this need a technician?#
When the checks are done and the display still shows Error Code, or the cabinet stays dark with a live socket. The manual says functional problems are not for the owner to resolve. 2
Systems a technician may investigate.
Several parts can lie behind this symptom. Noticing it does not prove that any single one has given out.

Wine cabinet electronic control
A Bertazzoni column wine cabinet keeps two temperature zones and shows them on its touch panel. The panel has On/Off, Home, Alarm and Back icons. Messages the manual lists are Power Failure, Door open, a zone too warm or too cold, Error Code and Check Cond. Touch Alarm to read a message with its number.

Wine cabinet condenser
The lower condenser of a Bertazzoni column wine cabinet sits behind the front toe kick cover. The manual asks for cleaning every 6 months with a soft brush vacuum, and a display reminder prompts it. Wait about 30 minutes after switching off, as the finned condenser must cool, and wear hand protection.
If the display adds a code.
When observation becomes a service request.
Leave internal testing to a technician.
The display shows Error Code and a number.
The socket is live and the Unit key is on, yet the cabinet does nothing.
The bottles are warm after the cabinet has run for 12 hours.
Check condenser appears right after a cleaning.
Arrange a diagnosticSources and model boundaries.
These sources back up the Bertazzoni wine cabinet will not turn on advice. Read the manual that belongs to your model.
- Built-in Columns Wine Cabinets / User manual (REF18WCPI*, REF24WCPI* /23)
- Built-in Columns Wine Cabinets / User manual (REF18WCPI*, REF24WCPI* /23)
Follow the book written for your own model. Read how we research these pages.
Why will my Bertazzoni wine column not start?
The manual asks four questions: is it plugged in, does the socket have power, is the Unit key active, and is the condenser clean. Answer those, then look for a code on the display.
What does Power Failure mean on the display?
A prolonged interruption of electrical power. The cabinet starts again automatically and shows the highest temperatures recorded during the outage.
How do I read an error code?
Touch the Alarm button. The message and its number show for 3 seconds. Press the info button to keep it on screen for 30 seconds, and write it down for the visit.
Is it safe to clean the condenser myself?
The manual describes cleaning it with the unit off and cooled, and warns that the edges are sharp, so protect your hands and arms.
Bertazzoni codes, symptoms, parts, service calls
Turn what the display says into a sensible next step.
Power Failure
"Power Failure" on a Bertazzoni column wine cabinet means mains power was cut for a long time. The cabinet restarts by itself and shows the highest temperatures recorded. Read them, then check how the wine has fared.
Bertazzoni wine cabinet will not turn on
The manual's first checklist for a wine column that does not work is short: power at the appliance, power at the socket, the Unit key, and a clean condenser. Do those before anything else, then read the display for a code.
Wine cabinet condenser
The lower condenser of a Bertazzoni column wine cabinet sits behind the front toe kick cover. The manual asks for cleaning every 6 months with a soft brush vacuum, and a display reminder prompts it. Wait about 30 minutes after switching off, as the finned condenser must cool, and wear hand protection.
Wine cooler repair
Book a diagnostic for your exact model, done at the appliance.
Find your metro
Office details, and what to tell us about getting in.