Start from the symptom
Bertazzoni freezer column freezer is not working.
If a Bertazzoni column freezer seems dead, check four things from the manual: power at the plug, the outlet, the Unit button, and demo mode. Lights on but no cooling is the demo-mode pattern, so do not rule it out because the display works.

Start with safe observations.
Turn the appliance off and unplug it before any check you do yourself. Look out for pooled water and sharp debris. Never touch a wet plug or the electrical parts, take off a service panel or go past what your model’s instructions allow.
- 1
Check the plug and outlet
The manual asks whether the freezer is connected and whether the socket has power. Plug in a lamp to test the outlet.
- 2
Press the Unit button
The manual asks whether the Unit button is active. Holding it for about 3 seconds switches the appliance off or on.
- 3
Think about demo mode
A showroom model can sit in a demo mode where lights and invented temperatures appear while nothing actually cools. The manual says to ask the seller to disable it.
- 4
Check for Sabbath mode
If the freezer cools but the lights and display are off, the manual says to check whether Sabbath mode was switched on by accident.
- 5
Read the message
Press the Alarm button and the display shows the error number. Photograph it before it returns to the home screen.
More about this symptom.
What are the first things to check?#
Four things: that the freezer is connected, that the socket has power, that the Unit button is active, and that the unit is not in demo mode. These come before any service call. 1
Why do the lights work but nothing cools?#
Demo mode can do this. The manual says a showroom-model freezer appears to operate, with lights and false temperatures, yet no cooling takes place. Sabbath mode is a separate case, where the cooling runs but the display stays dark. 2
What does an error code mean here?#
The Error Code message marks a functional problem the owner cannot fix. Touch Alarm to read the number, which stays up for 3 seconds. The manual treats it as a job for service. Note the number for the visit. 3
When can I stop waiting on an alarm?#
The manual says messages can appear on start-up or in unusual conditions. Silence the alarm with the Alarm button, leave the appliance running and keep door openings to a minimum for about 10 to 12 hours. 1
Systems a technician may investigate.
Several parts can lie behind this symptom. Noticing it does not prove that any single one has given out.

Column freezer electronic control
A Bertazzoni column freezer is run from a touch control panel that holds the temperature and shows messages. Its main icons are On/Off, Home, Alarm and Back. If something is wrong, touch Alarm to see the message and number. Power Failure!!, Door Unit OPEN, Replace filter and Check Cond are the printed messages.

Column freezer condenser
Behind the front toe kick cover of a Bertazzoni column freezer sits the condenser. The manual asks for cleaning every 6 months with a vacuum and a soft brush, and a display reminder prompts it. After cleaning, touch the reset icon to restart the 6-month timer.
If the display adds a code.
When observation becomes a service request.
Leave internal testing to a technician.
The display shows Error Code and a number.
Power Failure!! stays on after power returned.
The freezer is warm after 10 to 12 hours of running.
Nothing lights up even though the outlet works.
Arrange a diagnosticSources and model boundaries.
These sources back up the Bertazzoni column freezer is not working advice. Read the manual that belongs to your model.
- Built-in Columns Freezer / User manual (REF18FCIP*, REF24FCIP*, REF30FCIP* /23)
- Built-in Columns Freezer / User manual (REF18FCIP*, REF24FCIP*, REF30FCIP* /23)
- Built-in Columns Freezer / User manual (REF18FCIP*, REF24FCIP*, REF30FCIP* /23)
Follow the book written for your own model. Read how we research these pages.
Why are the lights on but my Bertazzoni freezer is not cold?
The manual describes a demo mode where the appliance seems to run, with lights and false temperatures, but does no cooling. If you suspect it, contact the seller to switch it off.
What does Power Failure!! mean?
The display message means a long interruption of electric power. The manual says the freezer restarts by itself and shows the warmest temperatures it reached.
How do I see an error number?
Touch the Alarm button and the error message appears with its number for 3 seconds. Press the info button to hold it on screen for 30 seconds.
Should I throw out food after an outage?
The manual does not give a food rule, so use your own judgment and check the warmest temperature the display recorded. Frozen food that has thawed and refrozen is the main concern.
Bertazzoni codes, symptoms, parts, service calls
Turn what the display says into a sensible next step.
Error Code...
"Error Code..." followed by a number on a Bertazzoni column freezer marks a functional problem the owner cannot solve. The manual prints no list of numbers. Write the number down and book a visit.
Bertazzoni column freezer is not working
If a Bertazzoni column freezer seems dead, check four things from the manual: power at the plug, the outlet, the Unit button, and demo mode. Lights on but no cooling is the demo-mode pattern, so do not rule it out because the display works.
Column freezer condenser
Behind the front toe kick cover of a Bertazzoni column freezer sits the condenser. The manual asks for cleaning every 6 months with a vacuum and a soft brush, and a display reminder prompts it. After cleaning, touch the reset icon to restart the 6-month timer.
Freezer repair
Book a diagnostic for your exact model, done at the appliance.
Find your metro
Office details, and what to tell us about getting in.